The LM139 and LM139A devices are characterized for operation over the full military temperature range of –55°C to +125°C. The LM239 and LM239A devices are characterized for operation from –25°C to +85°C. The LM339 and LM339 devices are characterized for operation from 0°C to 70°C. The LM2901, LM2901AV, and LM2901V devices are characterized for operation from –40°C to +125°C.
Features :
- Low Supply-Current Drain Independent of Supply Voltage: 0.8 mA (Typical)
- Low Input Bias Current: 25 nA (Typical)
- Low Input Offset Current: 3 nA (Typical) (LM139)
- Low Input Offset Voltage: 2 mV (Typical)
- Common-Mode Input Voltage Range Includes Ground
- Differential Input Voltage Range Equal to Maximum-Rated Supply Voltage: ±36 V
- Low Output Saturation Voltage
- Output Compatible With TTL, MOS, and CMOS
- On Products Compliant to MIL-PRF-38535, All Parameters Are Tested Unless Otherwise Noted. On All Other Products, Production Processing Does Not Necessarily Include Testing of All Parameters.
Applications :
- Power Supervision
- Oscillators
- Peak Detectors
- Logic Voltage Translation
- Inverter
LM339 Pinout :
Pin Configuration and Functions :
Absolute Maximum Ratings :
- VCC Supply voltage(2) 36 V
- VID Differential input voltage(3) ±36 V
- VI
Input voltage range (either input) –0.3 36 V
- IK Input current(4) –50 mA
- VO Output voltage 36 V
- IO Output current 20 mA
- TJ Operating virtual-junction temperature 150 °C